Example 1: replacing parts
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,RMI AP,[Maintenance], Replace,,Normal end,uid=maintenance,, from==xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,xxxxxxxxxx,,x,xxxxxxxxxx,xx xxxxxxxx, +Parts name=SSVP0
Example 2: replacing PDEV (physical device)
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,,
[Maintenance], Replace,,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PDEV=HDD000-00
+Copy=Restore Data
Detailed Information
Item |
Description |
---|---|
Parts name |
The name of the parts (SSVPx, SVP-BASIC, SVP-OPTION, HSNPANELx, PCIADP, PCICON) specified to be replaced |
Physical Device (PDEV) |
The mounting location of the PDEVs (physical devices) to be replaced |
Copy |
The status of copy process when replacing physical devices (PDEV)s. This information is output only when replacing PDEVs. Restore Data: Data recovery from spare disk, Correction Copy: correction copy |
Diagnosis |
Diagnosis is output only when INLINE skip is selected when replacing PDEVs. This information is output only when replacing PDEVs. |
Micro Program |