Example 1: installing a SM (shared memory)
09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Install,,Normal end,Seq.=xxxxxxxxxx +Shared Memory Function=[xxxxxxxx,xxxxxxxx]
Detailed Information for Example 1
Item |
Description |
---|---|
Shared Memory Function |
The shared memory name (for all shared memories including the installed shared memories) |
Example 2: installing a CHB or DKB
09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Install,,Normal end,Seq.=xxxxxxxxxx +Location=[xxx,xxx],Type=xxxx, Forcibly run without safety checks=Enable
Detailed Information for Example 2
Item |
Description |
---|---|
Location |
The mounting location of the CHB or DKB that was installed (CHB-xxx or DKB-xxx) |
Type |
The unit type of the CHB or DKB that was installed |
Forcibly run without safety checks |
Indicates whether the function of forcible replacement (without running safety checks) is enabled. |
Example 3: installing a drive unit
09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Install,,Normal
end,Seq.=xxxxxxxxxx
+{Location,Type}=[{DKU-xx,xxx},{DKU-xx,xxx},{DKU-xx,xxx}],
Num of Drive Units=3,Forcibly run without safety checks=Enable
Detailed Information for Example 3
Item |
Description |
---|---|
Location |
The mounting location of the drive unit that was installed (DKU-xx) |
Type |
The unit type of the drive unit that was installed |
Num of Drive Units |
The number of the drive units that were installed |
Forcibly run without safety checks |
Indicates whether the function of forcible replacement (without running safety checks) is enabled. |
Example 4: installing a drive
09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Install,,Normal end,Seq.=xxxxxxxxxx +Drives=[HDDxxx-xx,HDDxxx-xx,HDDxxx-xx],Num of Drives=3, Forcibly run without safety checks=Enable
Detailed Information for Example 4
Item |
Description |
---|---|
Drives |
The mounting location of the drive that was installed |
Num of Drives |
The number of the drives that were installed |
Forcibly run without safety checks |
Indicates whether the function of forcible replacement (without running safety checks) is enabled. |
Example 5: installing a DKC
09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Install,,Normal end,Seq.=xxxxxxxxxx +DKCs=[xxx,xxx,xxx,xxx],Num. of DKCs=4
Detailed Information for Example 5
Item |
Description |
---|---|
DKCs |
The mounting location (DKCx) of the DKC that was installed |
Num. of DKCs |
The number of DKCs that were installed |
Example 6: installing a CTL (including CTL L)
09XX,0,YYYY/MM/DD,HH:MM:SS.xxx,00:00,GUM,,[Maintenance],Install,,Normal end,Seq.=xxxxxxxxxx +CTLs=[xxx,xxx]
Detailed Information for Example 6
Item |
Description |
---|---|
CTLs |
The mounting location (CTLxx) of the CTL that was installed |