[Information] ORM Value

Audit Log User Guide for VSP 5000 Series

Version
90-08-8x
Audience
anonymous
Part Number
MK-98RD9010-12

Example 1: changing the threshold of the HDD

09xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,SVP,uid=user-name,,
[Information],ORM Value,Alter,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx 
+Type=7days 
+{Read Err.(Unrecovered),Read Err.(Recovered), Seek Err.(Recovered),
Seek Err.(Unrecovered),Not Ready, Other Errors}={15,1.00e-008,100,10,10,10}
++PDEV=[HDD000-01,HDD000-02],Num. of PDEVs=2

Example 2: changing the threshold of the SSD when drive type is SLxxx-MxxxSS/SNxxx-RxxxNC/SPxxx-YxxxNC

09xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,SVP,uid=user-name,,[Information],ORM Value,Alter,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx 
+Type=Total 
+{Total Defect Count,Used Endurance Indicator}={160000,(99,90)} 
++PDEV=[HDD000-03],Num. of PDEVs=1

Example 3: changing the threshold of the SSD when drive type is other than the ones in Example 2

09xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,SVP,uid=user-name,,[Information],ORM Value,Alter,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx 
+Type=Total 
+{Total Defect Count}={15} 
++PDEV=[HDD000-01,HDD000-02],Num. of PDEVs=2

Example 4: changing the threshold of the FMD when drive type is NFHxx-Pxxxxx

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,,
[Information],ORMValue,Alter,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx 
+Type=Today 
+{Total Defect Count,Reboot Error,DMA Error,Memory Error, Uncorrected Error,Used Endurance
Indicator,Battery Error, FMD Battery Life Indicator}={0,2,10,500,512,(0,0),1,0}
++PDEV=[HDD000-03],Num. of PDEVs=1

Example 5: changing the threshold of the FMD when drive type is NFHxx-Qxxxxx

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,,[Information],ORM Value,Alter,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx 
+Type=Today 
+{Total Defect Count,Reboot Error,DMA Error,Memory Error, Uncorrected Error,Used Endurance
Indicator,Capacitor Error}= {0,2,10,500,512,(0,0),1} 
++PDEV=[HDD000-03],Num. of PDEVs=1

Example 6: Error Reset

09xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,SVP,uid=user-name,,[Information],ORM Value,Error Reset,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+PDEV=HDD000-01

Basic Information

Parameter

Description

Alter

Change the threshold of ORM (Online Read Margin)

Error Reset

Indicates Error Reset

Detailed Information

Item

Description

Type

The period of time to acquire the result of threshold diagnosis using the read diagnosis function

Today: Current day only, 7days: 7 days, Total: Every operating days

Read Err. (Unrecovered)

The threshold of the Read Error (Unrecovered)

Read Err. (Recovered)

The threshold of the Read Error (Recovered)

Seek Err. (Recovered)

The threshold of the Seek Error (Recovered)

Seek Err. (Unrecovered)

The threshold of the Seek Error (Unrecovered)

Not Ready

The threshold of the Not Ready status.

Other Errors

The threshold of Other Errors.

Total Defect Count

The threshold of the Total Defect Count

Used Endurance Indicator

The threshold of the Used Endurance Indicator

Reboot Error

The threshold of the Reboot Error

DMA Error

The threshold of the DMA Error

Memory Error

The threshold of the Memory Error

Uncorrected Error

The threshold of the Uncorrected Error

Battery Error

The threshold of the Battery Error

FMD Battery Life Indicator

The threshold of the FMD Battery Life Indicator

Capacitor Error

The threshold of the Capacitor Error

PDEV

The mounting location of the PDEV (physical device) that is the target of Alter or error reset

Num. of PDEVs

The number of PDEVs (physical devices)