Modify RCU

Audit Log User Guide for VSP 5000 Series

Version
90-08-8x
Audience
anonymous
Part Number
MK-98RD9010-12

Example

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,,
[Config Command],,,Accept,from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,
Seq.=xxxxxxxxxx
+Command=Modify RCU
++S/N=512345,MCU=0xAAAA,RCU=0xBBBB,SSID=0x0123,Controller ID=8,
Path Gr. ID=0,Min.Path=1,Round Trip Time(ms)=30,RIO MIH(s)=3,
FREEZE=Enable

Detailed Information

Item

Description

Command

The command name

S/N

The serial number of the remote storage system

MCU

The CU number of the local storage system

"Free" is output when CU Free is specified.

RCU

The CU number of the remote storage system

"Free" is output when CU Free is specified.

SSID

The SSID of the remote storage system

No value is output when CU Free is specified.

Controller ID

The controller ID of the remote storage system

5: USP V/VM, 6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP E series, VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800, 19: HUS VM

No value is output when CU Free is not specified.

Path Gr. ID

The path group ID of the remote storage system

No value is output when CU Free is not specified.

Min.Path

The minimum number of paths between the local storage system and remote storage system

Round Trip Time(ms)

The round trip time: the delayed time for the remote I/O round trip

RIO MIH(s)

The value of the RIO MTH (remote I/O missing interrupt handler) timer: The wait time for data copy from the local storage system to the remote storage system to be complete

FREEZE

The setting status of the CGROUP (FREEZE/RUN) PPRC TSO command

Enable: Enabled, Disable: Disabled