Modify Journal

Audit Log User Guide for VSP 5000 Series

Version
90-08-8x
Audience
anonymous
Part Number
MK-98RD9010-12

Example

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,,
[Config Command],,,Accept,from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,
Seq.=xxxxxxxxxx
+Command=Modify Journal
++JNL=0xAAA,Timer Type=System,Use of Cache=Use,Inflow Control=Enable,
Data Over flow Watch(s)=600,MU=0,Copy Pace=Medium,
Path blockade watch timer Transfer=Enable,
Path blockade watch timer(m)=60,Entire Copy=-,Transfer Speed(Mbps)=-

Detailed Information

Item

Description

Command

The command name

JNL

The number of a journal whose options to be changed

Timer Type

The clock type used for consistency time

System: The system clock of the main frame host on the primary site

Local: No system clock is used.

None: The system clock of the main frame host on the primary site when data is copied from the storage system on the secondary site to the one on the primary site

Use of Cache

Indicates whether journal data in the restore journal is stored in cache or not

Not Use: Not stored in cache, Use: Stored in cache

Inflow Control

The setting status of data inflow

Enable: Enabled, Disable: Disabled

Data Over flow Watch(s)

The time for data over flow to be watched: 0 to 600 seconds

MU

The MU number

Copy Pace

The data transfer speed for copy operation

Low: Low speed, Medium: Medium speed, High: High speed

Path blockade watch timer Transfer

The setting status of the path blockade watch timer

Enable: Enabled, Disable: Disabled

Path blockade watch timer(m)

The path blockade watch time: 1 to 60 minutes

If the value is 0, the path blockade watch timer is disabled.

Entire Copy

The behavior of when Delta Sync fails

Enable: Copy the entire data on the primary volume to the secondary volume.

Disable: Not copy the data on the primary volume to the secodary volume.

Transfer Speed(Mbps)

The data transfer speed on the communication line