Delete RCU Path

Audit Log User Guide for VSP 5000 Series

Version
90-08-8x
Audience
anonymous
Part Number
MK-98RD9010-12

Example

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,,
[Config Command],,,Accept,from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,
Seq.=xxxxxxxxxx
+Command=Delete RCU Path
++S/N=512345,MCU=0xAAAA,RCU=0xBBBB,MCU Port=1A,RCU Port=1B,
SSID=0x0123,Controller ID=8,Path Gr. ID=0

Detailed Information

Item

Description

Command

The command name

S/N

The serial number of the remote storage system

MCU

The CU number of the local storage system

"Free" is output when CU Free is specified.

RCU

The CU number of the remote storage system

"Free" is output when CU Free is specified.

MCU Port

The port name of the local storage system

RCU Port

The port name of the remote storage system

SSID

The SSID of the remote storage system

Controller ID

The controller ID of the remote storage system

5: USP V/VM, 6: VSP, 7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP E series, VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800, 19: HUS VM

Path Gr. ID

The path group ID of the remote storage system

No value is output when CU Free is not specified.