Add RCU iSCSI Port

Audit Log User Guide for VSP 5000 Series

Version
90-08-8x
Audience
anonymous
Part Number
MK-98RD9010-12

Example

09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,Out-of-band,uid=user-name,,
[Config Command],,,Accept,from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,
Seq.=xxxxxxxxxx
+Command=Add RCU iSCSI Port
++S/N=512345,Controller ID=8,MCU Port=3B,RCU Port=4B,TCP Port=3260,
IP Address=192.168.0.169

Detailed Information

Item

Description

Command

The command name

S/N

The serial number of the remote storage system

Controller ID

The controller ID of the remote storage system

7: VSP G1000/G1500 and VSP F1500, 8: VSP 5000 series, 18: VSP E series, VSP G130, G/F350, G/F370, G/F700, G/F900, VSP G200, G400, G600, G800, and VSP F400, F600, F800, 19: HUS VM

MCU Port

The name of the port on the local storage system

RCU Port

The name of the port on the remote storage system

TCP Port

The TCP port number

A hyphen (-) is displayed if the TCP port number is not specified.

IP Address

The IP address of the port on the remote storage system