The following table provides details about the user completion codes.

Table. User completion codes

Completion codes

Explanation

U0003

There is a problem with the issued CCW.

The version of the registered user SVC might be old. Check whether the latest user SVC is registered by performing the following operations:

  • Using a CLI command:

    Execute the YKINSCHK command, and check that OK is displayed for User SVC Routine.

  • From the ISPF panel:

    From the Installation Verification Summary panel, check that OK is displayed for User SVC Routine.

U0128

The user does not have the permission to execute CLI commands. The user might not have the READ permissions for the profile required to execute CLI commands, or an RACF error occurred.

If the reason code is 00000010 or 00000030:
  • A profile to which READ permissions have not been granted: the STGADMIN.YKA.BCM.COMMANDS profile or the STGADMIN.YKA.BCM.YKQUERY profile

  • A command that cannot be executed: a CLI command for viewing the operations or status of copy pairs, paths, or command devices

If the reason code is 00000040, 00000050, or 00000070
  • A profile to which READ permissions have not been granted: the STGADMIN.YKA.BCM.COMMANDS profile

  • A command that cannot be executed: a CLI command for operating copy pairs, paths, or command devices

If the reason code is a value other than the above:

The information returned from the RACROUTE REQUEST=AUTH macro is displayed. For details, see the IBM manual Security Server RACROUTE Macro Reference.

U1009

An attempt was made to call a module that cannot be executed. There might be a problem in the LINKLIB library settings. Specify the installation dataset for the LINKLIB library.