The following table provides a list of general error conditions and provides recommended action for each condition.
Error |
Corrective action |
---|---|
The Device Manager - Storage Navigator computer or management client hangs, or TrueCopy operations do not function properly. |
|
An initiator channel-enabled LED indicator (on the control panel) is off or flashing. |
Contact customer support. |
The pairs or paths to the remote system or to the secondary storage system are not displaying correctly. |
Make sure that the correct CU is selected. |
A TrueCopy error message is displayed on the Device Manager - Storage Navigator computer or management client. |
Resolve the error, and then try the TrueCopy operation again. |
The remote system or secondary storage system path status is not normal. |
Check the path status (View Remote Connection Properties window of HDvM - SN, or the raidcom get rcu command of CCI ), and see Remote path status problems. |
Pair status is PSUE. |
See Split pair problems. |
The paircreate or pairresync operation resulted in a timeout error. |
|
There is a pinned track on a TrueCopy volume. |
See Pinned track recovery for more information. |
Monitoring data is not updated though the Monitoring Switch option is set to Enable. |
Because the time setting of SVP is changed, the monitoring data might not be updated. Disable Monitoring Switch, and then enable again. For more information about Monitoring Switch, see the Performance Guide of your storage system. |
A pair cannot be created or resynchronized. | Check if the controller board is blocked on the primary storage system. Restore the blocked controller board, and then retry the operation. |
The pair status remains unchanged as follows when creating a pair
or resynchronizing a pair:
|
|
The pair information remains on the volume after trying to delete the
pair, even if the pair is not created using the volume. The pair information remaining means that the volume cannot be used as a volume of a different pair. |
If the pair cannot be deleted or if the pair remains when the pair status
is verified after the pair deletion, perform the following
procedure:
|
(VSP 5000 series) Any of the following operations fails
in the 3DC cascade, 3DC multi-target, or 3DC delta resync
configuration with UR and TC using a volume connected to a host via
NVMe-oF:
|
See the Hitachi Universal Replicator User Guide and make sure that your configuration is a supported 3DC configuration. Also, check whether the microcode versions of all storage systems in the three sites support 3DC configurations using a volume connected to a host via NVMe-oF. If this condition is not met, update the microcode versions to meet the condition, and then retry the operation. |