Use this window to connect storage systems for remote replication.
For complete UR or URz information, see the section on configuring primary and secondary systems in the Hitachi Universal Replicator User Guide or Hitachi Universal Replicator for Mainframe User Guide.
When Select Type is Fibre:
When Select Type is iSCSI:
Item |
Description |
---|---|
Connection Type (VSP 5000 series) |
By default, System is selected. |
Local Storage System
Item |
Description |
---|---|
Model |
Local model. |
Serial Number |
Local serial number. |
Local CU (VSP 5000 series) |
Local system CU number (00 to FE), displayed when Connection Type is CU. A hyphen (-) is displayed when Connection Type is System. |
Remote Storage System
Item |
Description |
---|---|
Model |
Remote system's model.
HUS VM (19) and VSP E series, VSP G200, G400, G600, G800, VSP F400, F600, F800, VSP G/F350, G/F370, G/F700, G/F900 (18) can be selected only when System is selected for Connection Type. If a value other than the above is specified, it is regarded as a storage system that will be supported in the future. In this case, in the Remote Connections window, the specified value will be enclosed by parentheses, such as (255), is displayed. |
Serial Number |
Last five or six digits of the remote system serial number, as follows:
|
Remote CU (VSP 5000 series) |
Remote system CU number, displayed when Connection Type is CU. |
SSID (VSP 5000 series) |
Remote system SSID in hexadecimal (0004 to FFFE). Can be selected when Connection Type is CU. If there are two or more SSID numbers, clicking the minus (-) button deletes the SSID text box. |
Add SSIDs (VSP 5000 series) |
Clicking adds the SSID to the remote system. The maximum is four. This button is not displayed if four SSID numbers are already added. |
Remote Paths
Item |
Description |
---|---|
Path Group ID |
Path group identifier (00 to FF). Up to 64 path group IDs can be registered per storage system. Path group IDs can be selected when Connection Type is System. |
Minimum Number of Paths |
Minimum number of remote paths.
|
Select Type |
Select the port type.
|
Port ID (for local storage systems) |
Select the port identifier of the local storage system. |
Virtual Port ID (for local storage systems) |
Virtual port ID of the local storage system. Displayed when iSCSI is selected as the port type. |
Port ID (for remote storage systems) |
Select the port identifier of a remote storage system. A hyphen (-) is displayed if the number of valid paths is greater than the minimum number of paths. Clicking the hyphen deletes the text box of the port for the local and remote storage systems. |
IP address |
Select the IP type (IPv4 or IPv6) for the port of the remote storage system to enter the IP address. Displayed only when iSCSI is selected as the port type. |
TCP Port Number |
Enter the TCP port number of the remote storage system. Displayed only when iSCSI is selected as the port type. |
Add Paths |
Opens a dialog box for creating additional paths (maximum of eight). |
Options
Item |
Description |
---|---|
RIO MIH Time |
Time limit between 10 and 100 seconds for the data-transfer operation to complete (15 is the default). |
Roundtrip Time (msec.) |
TC, TCz and GAD only. Time limit between 1 and 500 milliseconds for data copy from P-VOL to S-VOL (1 is the default). |
FREEZE Option (Mainframe systems) |
Enables or disables support for the CGROUP (FREEZE/RUN) PPRC TSO command. Can be selected when Connection Type is CU. |