Configuration commands and options

TrueCopy® User Guide

Version
9.8.7
Audience
anonymous
Part Number
MK-98RD9022-18

The following table lists the TrueCopy configuration operations and provides the CCI commands and options for each operation.

For information about CCI commands, see the Command Control Interface Command Reference.

Operation

Option

Available in HDvM - SN?

CCI

command and options

Edit Ports (VSP 5000 series)

Port Attribute

Yes

raidcom modify port

-port_attribute port attribute

Add Remote Connection

Connection Type (VSP 5000 series)

Yes*

none

Remote Storage System

Yes*

raidcom add rcu

-rcu serial# mcu# rcu# id

Remote Paths

Yes*

raidcom add rcu

-cu_free serial# id pid

RIO MIH Time

Yes*

raidcom modify rcu

-rcu_option mpth rto rtt[fzd|fze]

Edit Remote Replica Options

Copy Type

Yes

none

Maximum Initial Copy Activities

Yes

raidcom modify remote_replica_opt

-copy_activity number of activities

Blocked Path Monitoring

Yes

raidcom modify remote_replica_opt

* In a configuration where VSP E590 or VSP E790 is connected to the following storage systems, you cannot perform operations involving remote paths from HDvM - SN on a storage system other than VSP E590 and VSP E790. Perform operations involving remote paths from CCI.
  • VSP G/F350, G/F370, G/F700, G/F900: microcode version earlier than 88-08-01-xx/xx
  • VSP E990: microcode version earlier than 93-04-01-xx/xx

In a configuration where the following storage systems are connected each other, you cannot perform operations involving remote paths from HDvM - SN on VSP 5000 series. Perform operations involving remote paths from CCI.