Remote path status definitions

TrueCopy® User Guide

Version
9.8.7
Audience
anonymous
Part Number
MK-98RD9022-18

You can understand the status of connections and paths better by knowing the definition of the status that you observe.

The following table provides remote path status descriptions.

Status

Definition

Normal

This path has been successfully established and can be used for TrueCopy remote copy activities.

Initialization Failed

The link initialization procedure with the secondary system has failed, because the physical path connection between either the primary and secondary system, or between the primary system and the host, was missing.

Communication Timeout

A timeout error has occurred between the primary and secondary system.

Path Rejected

The remote path link function has been rejected by the secondary system. All remote path resources in the secondary system might be used for other connections.

Serial Number Mismatch

The serial number of the control unit that is connected to this remote path does not match the serial number specified by the Add Remote Connection window.

Invalid Port Mode

The specified port does not have the initiator attribute.

RCU Port Number Mismatch

There are three possible causes:

  • The specified port in the secondary system is physically disconnected from the primary system.
  • The port is not configured as an RCU target port.
  • The specified port number is not available.

RCU Port Type Mismatch

The microcode on the remote side does not support the fibre remote copy function, or the specified port type is not RCU target.

Communication Failed

A timeout error has occurred on the path between the primary and secondary system.

Logical Blockade

This remote path was blockaded because a path error or a link error occurred continuously.

Program Error

This remote path was blockaded because a program error occurred.

In Progress

This remote path is in progress of changing the attribute of port.