The following versions are recommended. If you use an earlier version, the SATA drive information might not display correctly.
- For Thunder 9530V, Thunder 9520V, Thunder 9570V: version 0658 or later
- For Thunder 9580V, Thunder 9585V: version 1658 or later
The following table shows the system parameters that must be specified for ports on the Thunder 9500V storage system.
| Window Names | Parameters | Parameter Settings |
|---|---|---|
| System Startup Settings | Start Attribute | |
| Single Mode | Use when the Thunder 9500V is in a one-controller configuration. | |
| Dual Active Mode | Use when the Thunder 9500V is in a two-controller configuration.
Be sure to specify that Data Share Mode will be used. |
|
| Hot Stand-By Mode | Do not specify this parameter. | |
| Common 1 | Delay Planned Shutdown | Optional |
| OPTION 1 | SCSI Fibre Channel Common Options | Optional |
| OPTION 2 | SCSI Fibre Channel Common Options | Optional |
| Data Striping | Operation if the processor failure occurs | Reset of occurred |
| Inquiry Setting | Command Queuing Mode | ON |
| Vendor ID | HITACHI (default) | |
| Product ID | DF600F (default) | |
| ROM Microprogram Version | Optional | |
| RAM Microprogram Version | Optional | |
| WEB Title | Optional | |
| Port Type | Reset/LIP Mode | |
| Reset/LIP Mode (Signal) | Optional | |
| Reset/LIP Mode (Process) | Optional | |
| LIP Reset Mode | Optional | |
| Controller Option | RS232C Error Information Outflow Mode | Optional |
| Write and verify mode | ON | |
| Host Connection Mode | Host Connection Mode 1 | Standard Mode |
| Host Connection Mode 2 | HISUP Mode (do not specify any other parameter). | |