Workflow to perform when SIMs related to the pool capacity or the capacity ensured for writing were reported

Thin Image User Guide

Version
9.8.6
Audience
anonymous
Part Number
MK-98RD9020-16

(VSP E series) The following figures explain how to take action when 604xxx, 605xxx, or 606xxx has occurred.

*To resolve SIMs, add parity groups to create LDEVs, and then expand the pool. The required physical capacity can be calculated by using the following formula:

required-physical-capacity = (physical-capacity-of-pool / 
pool-threshold) – physical-capacity-of-pool-before-expansion

Note the threshold and the deletion rate used for the calculation are expressed as a fraction converted from a percent. For example, if the threshold is 80%, enter 80/100 as the pool threshold for the calculation.