The status of Thin Image (HTI) pairs depends on whether the hosts can read from or write to the Thin Image pair P-VOL or S-VOLs.
The following table explains the host access and pair status for snapshot pairs.
HTI pair status |
P-VOL |
S-VOL |
||
---|---|---|---|---|
Read |
Write |
Read |
Write |
|
SMPL |
Yes |
Yes |
No |
No |
SMPL(PD) or SMPP |
Yes |
Yes |
No |
No |
COPY |
Yes |
Yes |
No |
No |
PAIR/PFUL |
Yes |
Yes |
No |
No |
PSUS/PFUS |
Yes |
Yes |
Yes1 |
Yes |
COPY(RS-R) or RCPY |
Yes2 |
Yes |
No |
No |
PSUE |
Yes |
Yes |
No |
No |
1: When the cascade attribute is disabled for the
pair, access to the S-VOL might not be available if the usage rate
of the pool to which the P-VOL belongs is 100%. 2: The data of the S-VOL can be read when pairs are restored. Legend Yes: Hosts can access the volume No: Hosts cannot access the volume |
If a host connects to at least two ports, an abnormality can occur with ports that are not connected to S-VOLs rejecting access from hosts. To resolve these issues, close the software application that monitors volumes.