Check the following table for the problem. After resolving an error, retry the operation. If you cannot resolve the issue, contact customer support.
Symptom |
Possible causes and troubleshooting steps |
---|---|
Hitachi Device Manager - Storage Navigator cannot access an external volume. |
|
An external volume cannot be mapped. |
|
An external volume cannot be deleted. | Forcibly delete external volumes if you cannot disconnect the external storage system or external volumes due to causes, such as removing the external storage system before you delete external volumes. To forcibly delete external volumes, select Yes for "Do you want to execute the Delete External Volumes operation without writing the cache data to the volumes?" For details about the procedure, see Deleting an external volume mapping (on page 88). |
An external path is blocked. |
|
Action is required for a path status in the View External LUN Properties dialog box. | See Troubleshooting external path status. |
The volume in the external system cannot be found even after port discovery or volume discovery was performed. | Follow any instructions given in the error message or messages and then retry the operation. If the problem persists, see Troubleshooting port and volume discovery problems. |
As a result of the port discovery, the external storage system displayed as Unknown is added to External storage system, and the external storage system is not recognized. | The external storage system is connected by using a route that cannot be used as an external path. See Troubleshooting port and volume discovery problems. |
The external volume is blocked. |
|
The status of the external volume is Blockade. | When errors occur in all external paths, the local storage system changes
the status of the external volume to Blockade.
|
The ? sign displays in the LUN ID (Highest Priority) column of the Discovered External Volumes table in the Add External Volumes window. | A corresponding external volume was not found for the external path with
the highest priority. Look for problems with the connection to the external system that failed during volume discovery. Fix any problems, and perform the operation again. |
External volume discovery was not completed because of failure. | Look for problems with the connection to the external system; also verify
that the external volume is correctly configured in the external
system. Fix any problems, and then perform the operation again. If the error message indicates "An external volume that can be added was not found by the result of Volume Discovery. (error code: 00622-105241)", the external volume discovery might have failed because the external storage system is connected by using a route that cannot be used as an external path. See Troubleshooting port and volume discovery problems. |
After reconnecting an external volume or system, 10 minutes have passed but the status has not change from Checking. | Click Refresh on the Device Manager - Storage Navigator main window. If the status remains Checking, perform the reconnect operation again. |
After disconnecting an external volume or system, the status does not change. | Click Refresh on the Device Manager - Storage Navigator main window. Note that the time required for write processing from cache to the external volume depends on volume capacity. More time is required for larger volumes. Processing speed is about 20 MB/s. However, the processing speed also depends on the performance and status of the external storage system. |
(VSP 5000 series) A message saying that intervention is required is issued to the mainframe host. | The device status is currently changing. Wait a few minutes, and then
check the status again. When the transition of the device status has
completed normally, the device can be used immediately. If the device is blocked as a result of the status transition, see the row "The external volume is blocked." above. |
(VSP 5000 series) A message saying that the device is blocked is issued to the mainframe host. | See the row "The external volume is blocked." above. |
|
Take one of the following actions:
|
External target port discovery failed with error code: 00605-008966. |
The DKCMAIN microcode version and the Device Manager - Storage Navigator software version might not match with each other. Check the versions. If they do not match with each other, update the DKCMAIN microcode version, and then retry. If the same symptom occurs when the versions match with each other, contact customer support. |