The following versions are recommended. If you use an earlier version, the SATA drive information might not display correctly.
- For Thunder 9530V, Thunder 9520V, Thunder 9570V: version 0658 or later
- For Thunder 9580V, Thunder 9585V: version 1658 or later
The following table shows the system parameters that must be specified for ports on the Thunder 9500V storage system.
Window Names | Parameters | Parameter Settings |
---|---|---|
System Startup Settings | Start Attribute | |
Single Mode | Use when the Thunder 9500V is in a one-controller configuration. | |
Dual Active Mode | Use when the Thunder 9500V is in a two-controller configuration.
Be sure to specify that Data Share Mode will be used. |
|
Hot Stand-By Mode | Do not specify this parameter. | |
Common 1 | Delay Planned Shutdown | Optional |
OPTION 1 | SCSI Fibre Channel Common Options | Optional |
OPTION 2 | SCSI Fibre Channel Common Options | Optional |
Data Striping | Operation if the processor failure occurs | Reset of occurred |
Inquiry Setting | Command Queuing Mode | ON |
Vendor ID | HITACHI (default) | |
Product ID | DF600F (default) | |
ROM Microprogram Version | Optional | |
RAM Microprogram Version | Optional | |
WEB Title | Optional | |
Port Type | Reset/LIP Mode | |
Reset/LIP Mode (Signal) | Optional | |
Reset/LIP Mode (Process) | Optional | |
LIP Reset Mode | Optional | |
Controller Option | RS232C Error Information Outflow Mode | Optional |
Write and verify mode | ON | |
Host Connection Mode | Host Connection Mode 1 | Standard Mode |
Host Connection Mode 2 | HISUP Mode (do not specify any other parameter). |