Thunder 9500V

Universal Volume Manager User Guide

Version
9.8.6
Audience
anonymous
Part Number
MK-98RD9016-12

The following versions are recommended. If you use an earlier version, the SATA drive information might not display correctly.

  • For Thunder 9530V, Thunder 9520V, Thunder 9570V: version 0658 or later
  • For Thunder 9580V, Thunder 9585V: version 1658 or later

The following table shows the system parameters that must be specified for ports on the Thunder 9500V storage system.

Window Names Parameters Parameter Settings
System Startup Settings Start Attribute
Single Mode Use when the Thunder 9500V is in a one-controller configuration.
Dual Active Mode Use when the Thunder 9500V is in a two-controller configuration.

Be sure to specify that Data Share Mode will be used.

Hot Stand-By Mode Do not specify this parameter.
Common 1 Delay Planned Shutdown Optional
OPTION 1 SCSI Fibre Channel Common Options Optional
OPTION 2 SCSI Fibre Channel Common Options Optional
Data Striping Operation if the processor failure occurs Reset of occurred
Inquiry Setting Command Queuing Mode ON
Vendor ID HITACHI (default)
Product ID DF600F (default)
ROM Microprogram Version Optional
RAM Microprogram Version Optional
WEB Title Optional
Port Type Reset/LIP Mode
Reset/LIP Mode (Signal) Optional
Reset/LIP Mode (Process) Optional
LIP Reset Mode Optional
Controller Option RS232C Error Information Outflow Mode Optional
Write and verify mode ON
Host Connection Mode Host Connection Mode 1 Standard Mode
Host Connection Mode 2 HISUP Mode (do not specify any other parameter).