System Option Mode for connecting Sun StorEdge 6120/6320
When you connect Sun StorEdge 6120/6320 as an external storage system, you must set SOM 725 of the local storage system to ON. If SOM 725 is not set to ON, the external storage system might be blocked when performing maintenance tasks such as rebooting the controller of the external storage system before the firmware update.
For more information about using SOM 725, log on to the Hitachi Vantara Support Connect: https://knowledge.hitachivantara.com/Documents
System option parameters for connecting Sun StorEdge 6120/6320
The port must be configured as a target attached to a Windows host.
Set system parameters according to the following table. For connection parameters not shown, refer to the Sun StorEdge 6120/6320 system documentation.
On your local storage system, set system option mode 725 to ON for support of Sun online maintenance operation.
Parameter | Parameter Setting |
---|---|
port host | SUN |