Replacing all external paths

Universal Volume Manager User Guide

Version
9.8.6
Audience
anonymous
Part Number
MK-98RD9016-12

You can replace the primary and alternate paths used by an external volume. Doing this requires one path to remain in Normal status at all times.

The following figure shows one path used by an external volume remaining in a Normal status at all times.



  1. Disconnect external path A. See Disconnecting an external path.
  2. Disconnect the cable for external path A, then remove it. See Removing or replacing an external path.
  3. Make sure the cable for external path C is connected, and then add this path to an existing path group. See Adding an external path to an existing path group.
    When external path C status is Normal, then both external path B and external path C are set, and you can replace the next path.
  4. Disconnect external path B.
  5. Disconnect the cable for external path B, then remove it.
  6. Make sure the cable for external path D is connected, and then add this path to an existing path group.
    When external path D status is Normal, then both external path C and external path D are set. The paths have all been replaced.