Device Manager - Storage Navigator actions and CCI commands

Universal Volume Manager User Guide

Version
9.8.6
Audience
anonymous
Part Number
MK-98RD9016-12

The following table lists actions that you can perform for external volumes in Device Manager - Storage Navigator and the corresponding CCI commands.

Device Manager - Storage Navigator action CCI command
Add External Volumes raidcom add external_grp1,2

raidcom discover external_storage2

raidcom discover lun2

Delete External Volumes raidcom delete external_grp
Disconnect External Storage Systems raidcom disconnect external_grp
Reconnect External Storage Systems raidcom check_ext_storage external_grp
Edit External Volumes raidcom modify external_grp
Assign MP Unit raidcom modify external_grp
Disconnect External Volumes raidcom disconnect external_grp
Reconnect External Volumes raidcom check_ext_storage external_grp
Disconnect External Paths raidcom disconnect path1
Reconnect External Paths raidcom check_ext_storage path1
Edit External Path Configuration raidcom add path1,2

raidcom delete path1

Notes:
  1. The virtual port operations can only be performed by using CCI. For more information, see the Command Control Interface Command Reference.
  2. It is recommended to specify the -safety_check enable option to run the command. If the -safety_check enable option is not specified, a route from the external storage system to the local storage system might be disconnected. For more information, see Considerations for external paths.