ShadowImage

TrueCopy® User Guide

Version
9.8.5
Audience
anonymous
Part Number
MK-98RD9022-16

You can assign ShadowImage volumes to TC pairs, and you can assign TC volumes to SI pairs.

The following table shows the configurations that are possible.

TC volume

SI P-VOL

SI S-VOL

P-VOL

Yes

Yes

S-VOL

Yes

No

Note the following when sharing TC volumes with SI volumes.

  • L1 and L2 SI pairs can be shared with TC volumes. Both node and leaf S-VOLs are considered secondary volumes by TC.
  • SI is recommended for in-system copy operations. However, if SI is not installed, TC can be used to copy within the same storage system. This configuration requires at least one fibre channel or iSCSI cable loop.
  • The SI Quick Restore can be performed when the TC pair is suspended. For information about the Quick Restore operation, see the Hitachi ShadowImage® User Guide.