Switch connection

TrueCopy® User Guide

Version
9.8.5
Audience
anonymous
Part Number
MK-98RD9022-16
The following figure shows a switch connection.

Some switch vendors require F port connectivity (for example, McData ED5000).

As shown in the following table, Fab settings, topology settings, and available link speed depend on the settings of the packages and protocols used for the storage system connections, as well as whether the host mode option 51 is used.

For details about HMOs, see the Provisioning Guide for the storage system.

Package name

Protocol

HMO 51 setting

Fabric setting

Topology: Initiator and RCU Target

Link speed that can be specified

CHB(FC32G)

32GbpsFC

OFF

ON

Point-to-Point

  • 4 Gbps
  • 8 Gbps
  • 16 Gbps
  • 32 Gbps
CHB(FC32G) (VSP G/F350, G/F370, G/F700, G/F900, VSP E series)

32GbpsFC

ON

ON

Point-to-Point

  • 4 Gbps
  • 8 Gbps
  • 16 Gbps
  • 32 Gbps
CAUTION:
HMO51 should only be used with configurations more than 1 km in distance. If HMO51 is set with a distance of less than 1 km, a data transfer error might occur on the secondary system.