Fibre Channel requirements

TrueCopy® User Guide

Version
9.8.5
Audience
anonymous
Part Number
MK-98RD9022-16

The primary and secondary systems must be connected using multimode or single-mode optical fibre cables. As shown in the following table, the cables and data path relay equipment required depend on the distance between the P-VOL and S-VOL storage systems.

Distance

Fibre cable type

Data path relay equipment

0 km to 1.5 km (4,920 feet)

Multimode shortwave Fibre Channel interface cables.

Switch is required for 0.5 km to 1.5 km.

1.5 km to 10 km (4,920 feet to 6.2 miles)

Single-mode longwave2 optical fibre cables.

Not required.

10 km to 30 km (6.2 miles to 18.6 miles)

Single-mode longwave2 Fibre Channel interface cables.

Switch is required.

Greater than 30 km (18.6 miles)1

Communications lines are required.

Approved third-party channel extender products.3

Notes:

  1. TrueCopy operations typically do not exceed 30 km.
  2. Longwave cannot be used for FCoE.
  3. For more information about approved channel extenders, contact Hitachi Vantara.

With Fibre Channel connections using switches, no special settings are required for the physical storage system.

Direct connections up to 10 km with single-mode longwave Fibre Channel interface cables are supported. Using the long-distance cables (longwave and communication line) causes the transfer performance degradation and the increased transfer delay depending on the connection distance. Make sure to verify the I/O performance before the installation of the long-distance cable. If the 10 km longwave cable is used, the transfer delay of about 0.1 ms occurs and the transfer speed is about 2 Gbps per port.

Customer support can provide the latest information about the availability of serial-channel TrueCopy connections.