Pair status before and after a split operation (VSP 5000 series)

TrueCopy® User Guide

Version
9.8.5
Audience
anonymous
Part Number
MK-98RD9022-16

Pairs in the same consistency group must be in PAIR/Duplex status when you begin the split operation in order to maintain consistency. Otherwise, when the operation completes, pair status will be inconsistent.

This is shown in the following table, in which font angle indicates the following:

  • Italics font: Pair status before the split operation on the consistency group
  • Regular font: Status after the split operation

For CCI

Pair statuses

TCz pairs

All = Duplex

Some = Duplex, some = Suspend

All = Suspend

TC pairs

All = PAIR

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

Some = PAIR, some = PSUS

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

All = PSUS

TC: PSUS

TCz: Duplex

TC: PSUS

TCz: Duplex/Suspend

TC: PSUS

TCz: Suspend

For BCM

Pair statuses

TCz pairs

All = Duplex

Some = Duplex, some = Suspend

All = Suspend

TC pairs

All = PAIR

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

Some = PAIR, some = PSUS

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

All = PSUS

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend

TC: PSUS

TCz: Suspend