Use this window of the Create SI Pairs wizard to select LDEVs that are P-VOLs.
This window contains the following tables:
- Available LDEVs table
- Selected LDEVs table
The following image shows this window of the Create SI Pairs wizard.
The following table describes items in this window.
Item |
Description |
---|---|
Selection Object (VSP E series) |
Filters LDEVs in the Available LDEVs table according to port type. Values:
|
Port ID |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. Filters LDEVs in the Available LDEVs table according to the port ID. Default: Any |
Host Group Name |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. Filters LDEVs in the Available LDEVs table by the host group name. This item is displayed if you select a Fibre Channel port for Port ID. Default: Any |
iSCSI Target Alias |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. Filters LDEVs in the Available LDEVs table by the iSCSI target alias. This item is displayed if you select an iSCSI port for Port ID. Default: Any |
Available LDEVs table
This table is displayed on the Select Primary Volumes window.
The following table describes the items in this table.
Item |
Description |
---|---|
LDEV ID |
The LDEV's identifier. |
LDEV Name |
The LDEV's name. |
Port ID |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. The port name of the LDEV's LUN path. |
Host Group Name / iSCSI Target Alias |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. The host group name and ID or iSCSI target alias and ID of the LDEV's LUN path. |
iSCSI Target Name |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. The iSCSI target name. |
LUN ID |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. The LUN identifier of the LDEV's LUN path. |
Provisioning Type |
The LDEV's provisioning type. Values:
|
Attribute |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. The LDEV's attribute. Values:
If the attribute is not set, a hyphen (-) is displayed. |
Emulation Type (VSP 5000 series) |
The LDEV's emulation type. |
Capacity |
The LDEV's capacity. |
CLPR |
The LDEV's CLPR ID. |
Encryption |
Encryption information.
A hyphen (-) is displayed if the LDEV is an external volume or migration volume. When the LDEV is a DP-VOL, the pool to which LDEV belongs is an external volume or blocked. |
Capacity Saving |
Information about the LDEV's capacity saving function.
|
Compression Acceleration | Compression accelerator settings.
|
T10 PI |
The LDEV's T10 PI attribute.
|
Number of Secondary Volumes |
The total number of S-VOLs assigned to the P-VOL. This value includes the volumes for pairs that you are creating, volumes in existing pairs. When ShadowImage is selected for Copy Type, the number of S-VOLs for the L1 P-VOL does not include the number of L2 S-VOLs. |
Add button |
Click to move the selected LDEVs from the Available LDEVs table to the Selected LDEVs table. |
Remove button |
Click to move the selected LDEVs from the Selected LDEVs table to the Available LDEVs table. |
Selected LDEVs table
This table is displayed on the Select Primary Volumes window.
The following table describes the items in this table.
Item |
Description |
---|---|
LDEV ID |
The selected P-VOL's LDEV identifier. |
LDEV Name |
The selected P-VOL's LDEV name. |
Port ID |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. The port name of the LDEV's LUN path. |
Host Group Name / iSCSI Target Alias |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. The host group name and ID or iSCSI target alias and ID of the LDEV's LUN path. |
iSCSI Target Name |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. The iSCSI target name. |
LUN ID |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. The LUN identifier of the LDEV's LUN path. |
Provisioning Type |
The LDEV's provisioning type. Values:
|
Attribute |
Not displayed when ShadowImage for Mainframe is selected for Copy Type. The LDEV's attribute. Values:
If the attribute is not set, a hyphen (-) is displayed. |
Emulation Type (VSP 5000 series) |
The LDEV's emulation type. |
Capacity |
The LDEV's capacity. |
CLPR |
The LDEV's CLPR ID. |
Encryption |
Encryption information.
A hyphen (-) is displayed if the LDEV is an external volume or migration volume. When the LDEV is a DP-VOL, the pool to which LDEV belongs is an external volume or blocked. For an external volume or migration volume, a hyphen (-) is displayed. |
Capacity Saving |
Information about the LDEV's capacity saving function.
|
Compression Acceleration | Compression accelerator settings.
|
T10 PI |
The LDEV's T10 PI attribute.
|
Number of Secondary Volumes |
The total number of S-VOLs assigned to the P-VOL. This value includes the volumes for pairs that you are creating, volumes in existing pairs. When ShadowImage is selected for Copy Type, the number of S-VOLs for the L1 P-VOL does not include the number of L2 S-VOLs. |