Primary Volume
|
The P-VOL information.
Values:
- LDEV ID: The P-VOL's LDEV identifier.
- LDEV Name: The P-VOL's LDEV name.
- Port ID: Port name of the P-VOL LDEV's LUN path.
- Host Group Name / iSCSI Target Alias: The host group name and ID or iSCSI target alias and ID of the P-VOL LDEV's LUN path.
- iSCSI Target Name: The P-VOL's iSCSI target name.
- LUN ID: The LUN identifier of the P-VOL LDEV's LUN path.
- Attribute: The P-VOL's attribute.
- (VSP 5000 series)
Emulation
Type: The P-VOL's emulation type.
- Capacity: The P-VOL's volume capacity.
- CLPR: The P-VOL's CLPR ID.
- Encryption: The P-VOL's encryption information.
A hyphen (-) is displayed if the P-VOL is an external volume or migration volume. When the P-VOL is a DP-VOL, the pool to which a P-VOL's LDEV belongs in an external volume or blocked.
- Capacity Saving: Information about the P-VOL's capacity saving function.
- Compression: The compression function is used.
- Deduplication and Compression: The deduplication function and the compression function are used.
- Disabled: The capacity saving function is not used.
- Compression Acceleration: Compression accelerator
settings.
- Enabled: The compression accelerator
setting is enabled.
- Disabled: The compression accelerator
setting is disabled.
- - (hyphen): The compression
accelerator setting is not available for an LDEV. Alternatively, the
compression accelerator setting is available for an LDEV whose capacity
saving setting is Disabled and whose capacity saving
status is Disabled.
- T10 PI: The P-VOL's T10 PI attribute information.
- Enabled: The P-VOL's T10 PI attribute is enabled.
- Disabled: The P-VOL's T10 PI attribute is disabled.
For SIz pairs, a hyphen (-) is displayed.
For SIz, Port ID, Host Group Name / iSCSI Target Alias, iSCSI Target Name, LUN ID, and Attribute are not displayed.
|
Copy Type
|
The types of pairs.
Values:
- SI-L1: SI L1
- SI-L2: SI L2
- (VSP 5000 series)
SIMF: SIz
|
Secondary Volume
|
The S-VOL information.
Values:
- LDEV ID: The S-VOL's LDEV identifier.
- LDEV Name: The S-VOL's LDEV name.
- Port ID: Port name of the S-VOL LDEV's LUN path.
- Host Group Name / iSCSI Target Alias: The host group name and ID or iSCSI target alias and ID of the S-VOL LDEV's LUN path.
- iSCSI Target Name: The S-VOL's iSCSI target name.
- LUN ID: The LUN identifier of the S-VOL LDEV's LUN path.
- Attribute: The S-VOL's attribute.
- (VSP 5000 series)
Emulation
Type: The S-VOL's emulation type.
- Capacity: The S-VOL's volume capacity.
- CLPR: The S-VOL's CLPR ID.
- Encryption: The S-VOL's encryption information.
A hyphen (-) is displayed if the S-VOL is an external volume or migration volume. When the S-VOL is a DP-VOL, the pool to which S-VOL's LDEV belongs is an external volume or blocked.
- Capacity Saving: Information about the S-VOL's capacity saving function.
- Compression: The compression function is used.
- Deduplication and Compression: The deduplication function and the compression function are used.
- Disabled: The capacity saving function is not used.
- Compression Acceleration: Compression accelerator
settings.
- Enabled: The compression accelerator
setting is enabled.
- Disabled: The compression accelerator
setting is disabled.
- - (hyphen): The compression
accelerator setting is not available for an LDEV. Alternatively, the
compression accelerator setting is available for an LDEV whose capacity
saving setting is Disabled and whose capacity saving
status is Disabled.
- T10 PI: The S-VOL's T10 PI attribute information.
- Enabled: The S-VOL's T10 PI attribute is enabled.
- Disabled: The S-VOL's T10 PI attribute is disabled.
For SIz pairs, a hyphen (-) is displayed.
For SIz, Port ID, Host Group Name / iSCSI Target Alias, iSCSI Target Name, LUN ID, and Attribute are not displayed.
|
Split Type
|
The split type.
Values:
- (VSP 5000 series)
Non Split:
The pair is not split.
- Quick Split: The pair is split, and then the data is copied so that the S-VOL is immediately available for read and write I/O. Any remaining differential data is copied to the S-VOL in the background.
- Steady Split: Differential data is copied, and then the pair is split.
|
Copy Pace
|
The system option that determines the rate at which you want the storage system to copy data.
Values:
- Slower: Improved host
server
I/O performance but slower processing speed.
- Medium: Average processing speed and host
server
I/O performance.
- Faster: Faster processing speed but slower host
server
I/O performance.
|
Mirror Unit
|
The mirror unit number.
|