You must set up and prepare the P-VOLs and S-VOLs for SI pairing before creating SI pairs. The volumes you use must meet the requirements for pair volumes.
The following table provides example volumes to guide you in preparing volumes for SI pairing.
CU |
Port |
GID: LUN |
Pair Volume Type |
Associated L1 S-VOLs |
Associated L1 P-VOLs |
Associated L2 S-VOLs |
Associated L2 P-VOL |
---|---|---|---|---|---|---|---|
0 |
1A |
0:00 |
L1 P-VOL |
1B-0:00, 2A-0:00, 2B-0:00 |
N/A |
N/A |
N/A |
0 |
1A |
0:01 |
L1 P-VOL |
1B-0:01, 2A-0:01, 2B-0:01 |
N/A |
N/A |
N/A |
0 |
1B |
0:00 |
L1 S-VOL L2 P-VOL |
N/A |
1A-0:00 |
3A-0:00, 3A-0:01 |
N/A |
0 |
1B |
0:01 |
L1 S-VOL L2 P-VOL |
N/A |
1A-0:00 |
3B-0:00, 3B-0:01 |
N/A |
0 |
2A |
0:00 |
L1 S-VOL L2 P-VOL |
N/A |
1A-0:00 |
4A-0:00, 3B-0:01 |
N/A |
0 |
2A |
0:01 |
L1 S-VOL L2 P-VOL |
N/A |
1A-0:00 |
4B-0:00, 3B-0:01 |
N/A |
0 |
3A |
0:00 |
L2 S-VOL |
N/A |
N/A |
N/A |
1B-0:00 |
0 |
3A |
0:01 |
L2 S-VOL |
N/A |
N/A |
N/A |
1B-0:00 |