Standard required time for FMDs

Volume Shredder User Guide

Version
9.6.0
Audience
anonymous
Part Number
MK-98RD9018-04

The following tables show the standard required times for shredding for FMDs.

For VSP 5000 series:

Number of parity groups RAID level Standard required time*
From 1 to 4 RAID 1 2D+2D 20 minutes
RAID 5 3D+1P 10 minutes
7D+1P 10 minutes
RAID 6 6D+2P 10 minutes
14D+2P 10 minutes
*FMD capacity is assumed to be 1 TB.

For VSP Fx00 models and VSP Gx00 models:

Drive capacity RAID level Standard required time (minute)
VSP G350/VSP F350 VSP G370/VSP F370 VSP G700/VSP F700 VSP G900/VSP F900
3.2 TB RAID 1 2D+2D 5 5 5 5
RAID 5 3D+1P 5 5 5 5
4D+1P 5 5 5 5
6D+1P 5 5 5 5
7D+1P 5 5 5 5
RAID 6 6D+2P 5 5 5 5
12D+2P 5 5 5 5
14D+2P 5 5 5 5
6.4 TB, 13.0 TB RAID 1 2D+2D 10 10 10 10
RAID 5 3D+1P 5 5 5 5
4D+1P 5 5 5 5
6D+1P 5 5 5 5
7D+1P 5 5 5 5
RAID 6 6D+2P 5 5 5 5
12D+2P 5 5 5 5
14D+2P 5 5 5 5