The following table shows the range of parameters that can be set for CCI options. For details about CCI commands, see the Command Control Interface Command Reference.
|
Parameter |
Range |
|---|---|
|
Mirror ID (MU#) |
0 |
|
CTG ID |
0 to 127 |
|
Path group ID |
0 to 255 |
|
Maximum initial copy activities |
1 to 512 |
|
Maximum initial copy activities per CU |
1 to 16 |
|
Blocked path monitoring time |
2 to 200 seconds The range is 2 to 45 seconds when the DKCMAIN firmware version is earlier than A3-04-21-xx/xx. The same range of values is used for TrueCopy, Universal Replicator, and global-active device. |
|
Blocked path SIM monitoring time |
2 to 200 seconds The range is 2 to 100 seconds when the DKCMAIN firmware version is earlier than A3-04-21-xx/xx. The same range of values is used for TrueCopy, Universal Replicator, and global-active device. |