Parameter range for CCI options

True Copy User Guide for VSP One Block

Version
10.4.x
Audience
anonymous
Part Number
MK-23VSP1B020-04

The following table shows the range of parameters that can be set for CCI options. For details about CCI commands, see the Command Control Interface Command Reference.

Parameter

Range

Mirror ID (MU#)

0

CTG ID

0 to 127

Path group ID

0 to 255

Maximum initial copy activities

1 to 512

Maximum initial copy activities per CU

1 to 16

Blocked path monitoring time

2 to 200 seconds

The range is 2 to 45 seconds when the DKCMAIN firmware version is earlier than A3-04-21-xx/xx.

The same range of values is used for TrueCopy, Universal Replicator, and global-active device.

Blocked path SIM monitoring time

2 to 200 seconds

The range is 2 to 100 seconds when the DKCMAIN firmware version is earlier than A3-04-21-xx/xx.

The same range of values is used for TrueCopy, Universal Replicator, and global-active device.