Data Retention Utility

True Copy User Guide for VSP One Block

Version
10.4.x
Audience
anonymous
Part Number
MK-23VSP1B020-04

You can create a TC pair using volumes that have been assigned the access attribute by the Data Retention Utility (DRU). However, you cannot specify a volume with the "S-VOL Disable" attribute as a TC S-VOL.

The following table shows whether a DRU volume with the specified access attribute can be used as a TC P-VOL or S-VOL.

DRU access attribute

Availability of TC P-VOL or S-VOL

P-VOL

S-VOL

Read/Write

Yes

Yes

Read Only

Yes

Yes

Protect

Yes

Yes

S-VOL Disable

Yes

No

Read Only and S-VOL Disable

Yes

No

Protect and S-VOL Disable

Yes

No

The following tables show TC volumes and status with the Data Retention Utility operations that can be performed using CCI.

TC

Volume

PAIR

status

DRU operation

Changing access attribute

Referring

access

attribute

Read/Write

Read Only

Protect

S-VOL

Disable

P-VOL

SMPL

Yes

Yes

Yes

Yes

Yes

COPY

Yes

Yes

Yes

Yes

Yes

PAIR

Yes

Yes

Yes

Yes

Yes

PSUS

Yes

Yes

Yes

Yes

Yes

PSUE

Yes

Yes

Yes

Yes

Yes

S-VOL

SMPL

Yes

Yes

Yes

Yes

Yes

COPY

Yes

Yes

Yes

No

Yes

PAIR

Yes

Yes

Yes

No

Yes

PSUS

Yes

Yes

Yes

Yes

Yes

PSUE

Yes

Yes

Yes

Yes

Yes