You can set an NVM subsystem port to the NVM subsystem. For the NVM subsystem port, specify a channel port to establish the network connection with the NIC for the host. By setting the NVM subsystem port, the communication path between the host, the NVM subsystem, and the logical volume is configured through the channel port.
You can set up the subsytem port once the NVM subsystem is created.
To make the data I/O path between the NVM subsystem and the host redundant, define multiple channel ports as the NVM subsystem ports to configure a redundant path.
You can define one channel port for an NVM subsystem port for each command. When creating a redundant path configuration, repeat running the command the same number of times as the number of channel ports to be used. For details about how to execute each CCI command and specify options, see the Command Control Interface Command Reference.