Access attribute restrictions

Provisioning Guide for VSP One Block

Version
10.2.x
Audience
anonymous
Part Number
MK-23VSP1B012-00

Some restrictions apply when you use products or functions on a volume that has an access attribute assigned to it.

Virtual LUN

  • You cannot convert volumes that do not have the read/write attribute into spaces.
  • You cannot initialize customized volumes that do not have the read/write attribute.

CCI

  • You can use CCI to make some Data Retention Utility settings. You can view some of the settings in the DRU user interface.
  • When using the DRU, another user might be using CCI to change an access attribute of a volume. If the CCI user changes an access attribute of a volume when you are using the DRU, you will be unable to change the access attribute of the volume by using DRU. If you attempt to change the access attribute of the volume by using the DRU, an error occurs. If the error occurs, refresh the display, then retry changing the access attribute of the volume.

Automatically started software

If any software that can start automatically is enabled, you must do one of the following:

  • Perform DRU operations when the program is not running.
  • Cancel the setting of the program start time.

Some software is likely to start automatically at the time specified by the user. For example, if a Volume Migration user specifies the time for starting the monitor, the monitor will automatically start at the specified time.