PD_RGC

Ops Center Analyzer REST API Reference Guide

Version
11.0.x
Audience
anonymous
Part Number
MK-99ANA003-18

The PD_RGC record holds performance data indicating configuration information for a parity group. This is a multi-instance record. The following records are not generated:

  • Records for external volume groups or virtual volume groups (Copy-on- Write Snapshot, Thin Image, and Dynamic Provisioning virtual volume groups)
  • Records for parity groups without a logical device

Collection Interval

3600

Key Field

RAID_GROUP_NUMBER

Lifetime

From when the parity group is set up to when it is removed.

Fields

Field Name

Description

Access Type

Format

CLPR_NUMBER

Number of the CLPR to which the parity group has been assigned.

1, 2

string(8)

COLLECTION_TIME

Time (in GMT) when the data was collected from the storage system.

1, 2

time_t

DISPLAY_DRIVE_TYPE

Type of drive making up the parity group (display name).2

1, 2, 3, 4

string(32)

DRIVE_TYPE

Type of drive making up the parity group.1, 2

1, 2, 3, 4

string(16)

INPUT_RECORD_TYPE

Record type identifier, which is always set to RGC.

1, 2, 3, 4

string(8)

INTERVAL

Interval (in seconds) at which information is collected.

1, 2, 3, 4

ulong

POOL_ID

This field cannot be used because it is reserved.

--

--

RAID_GROUP_NUMBER

Parity group number.

1, 2, 3, 4

string(64)

RAID_GROUP_TYPE

This field cannot be used because it is reserved.

--

--

RAID_LEVEL

RAID level of the parity group.

1, 2, 3, 4

unsigned char

RAID_TYPE

Combination of the RAID level and HDU of the parity group:

  • ExampleRAID5(3D+1P)

Note that the following format is used for a volume split from a distributed parity group:

  • Example when the Access Type is 1 or 2

    RAID1(4D+4D)

  • Example when the Access Type is 3 or 4

    RAID1(2D+2D)x2

1, 2, 3, 4

string(32)

RECORD_TIME

Record creation time (in GMT).

1, 2, 3, 4

time_t

SLPR_NUMBER

This field cannot be used because it is reserved.

--

--

Notes:

  1. FMC is the value used when the drive type is FMC, FMD DC2, or FMD HDE.
  2. For VSP 5000 series SCM drives, the information depends on the storage system microcode version:
    • If the microcode version is earlier than version 90-04-04, an SCM drive is shown as an SSD drive (SSD NVMe).
    • If the microcode version is 90-04-04 or later, an SCM drive is shown as an SCM drive (SCM NVMe).