You should understand the I/O actions on the P-VOL and the S-VOL of a GAD pair.

The following table lists and describes the GAD I/O modes. As shown in the following table, the I/O mode terms displayed by the user interfaces are slightly different.

I/O mode

Read processing

Write processing
I/O mode CCI 1 Storage Navigator
Mirror (RL) L/M Mirror (Read Local) Sends data from the storage system that received a read request to the server. Writes data to the P-VOL and then the S-VOL.
Local L/L Local Sends data from the storage system that received a read request to the server. Writes data to the volume on the storage system that received a write request.
Block2 B/B Block Rejected (Replies to illegal requests). Rejected (Replies to illegal requests).
  1. In CCI, the I/O mode is displayed as read processing/write processing in which L indicates Local, M indicates Mirror, and B indicates Block (for example, L/L indicates Local read processing and Local write processing).
  2. For volumes whose I/O mode is Block, a response indicating that the LU is undefined is returned to the Report LUN and Inquiry commands. Therefore, servers cannot identify a volume whose I/O mode is Block, or the path of this volume is blocked.