You should know how GAD pairs and Universal Replicator pairs work together for different pair statuses for GAD pairs or UR pairs.

The following table shows GAD pair operations and whether they can be performed (Yes or No) with the listed UR pair status.

Table. GAD operations and UR pair statuses
UR pair status Attribute of the target UR pair GAD pair operation
Create pairs1 Split pairs Suspend pairs Resynchronize pairs Delete pairs
P-VOL specified S-VOL specified P-VOL specified S-VOL specified P-VOL or S-VOL specified

COPY

P-VOL

No

Yes

No

Yes

Yes

No2

S-VOL

No

No3

No

No

No

No2

PAIR

P-VOL

No

Yes

No

Yes

Yes

No2

S-VOL

No

No3

No

No

No

No2

PSUS

P-VOL

No

Yes

No

Yes

Yes

No2

PSUE

P-VOL

No

Yes

No

Yes

Yes

No2

S-VOL

No

No3

No

No

No

No2

SSUS

S-VOL

No

No3

No

No

No

No2

SSWS

S-VOL

No

No3

No

No

No

No2

HOLD

P-VOL

No

No

Yes

No

No

No2

S-VOL

No

No

No

No

No

No2

HLDE

P-VOL

No

No

Yes

No

No

No2

S-VOL

No

No

No

No

No

No2

Note:
  1. When creating a GAD and UR configuration, create a GAD pair first.
  2. When deleting a GAD pair, delete the UR pair and the UR delta resync pair first.
  3. The UR S-VOL is also used as the GAD P-VOL only when the UR S-VOL is duplicated using GAD. In this case, the GAD P-VOL status must be PSUS, therefore, the pair split terminates abnormally.

The following table shows UR pair operations and whether they can be performed (Yes or No) with the listed GAD pair status.

Table. UR pair operations and GAD pair statuses
GAD pair status I/O mode Attribute of the target GAD pair UR pair operation
Create pairs Split pairs Suspend pairs Resynchronize pairs
P-VOL specified S-VOL specified P-VOL specified S-VOL specified

INIT/COPY

Mirror (RL)

P-VOL

No

Yes

No

Yes1

No

Block

S-VOL

No

No

No

No

No

COPY

Mirror (RL)

P-VOL

No

Yes

No

Yes1

No

Block

S-VOL

No

No

No

No

No

PAIR

Mirror (RL)

P-VOL

Yes2

Yes

No

Yes1

No

S-VOL

No

No

No

No

No

PSUS

Local

P-VOL

No

Yes

Yes3

Yes1

Yes3

Block

P-VOL

No

Yes

Yes3

No

No

PSUE

Local

P-VOL

No

Yes

Yes3

Yes1

Yes3

Block

P-VOL

No

Yes

Yes3

No

No

SSUS

Block

S-VOL

No

No

No

No

No

SSWS

Local

S-VOL

No

Yes

No

Yes

No

Note:

  1. Can be performed only when the UR delta resync pair status is HLDE.

  2. GAD pairs can be used with UR pairs only when the volume specified as the UR S-VOL is a UR delta resync S-VOL.
  3. The UR S-VOL is also used as the GAD P-VOL only when the UR S-VOL is duplicated using GAD.

The following table shows UR delta resync pair operations and whether they can be performed (Yes or No) with the listed GAD pair status.

Table. UR delta resync pair operations and GAD pair statuses
GAD pair status I/O mode Attribute of the target GAD pair UR delta resync pair operation
Create UR delta resync pair Delta resync Delete pairs
P-VOL specified S-VOL specified UR delta resync P-VOL UR delta resync S-VOL
INIT/COPY Mirror (RL) P-VOL No No1 Yes No No No
Block S-VOL No No1 No No No No
COPY Mirror (RL) P-VOL No No1 Yes No No No
Block

S-VOL

No No1 No No No No
PAIR Mirror (RL) P-VOL No

No1

Yes

No

No No
S-VOL Yes No1 No No Yes4 No
PSUS Local P-VOL No No1 Yes Yes3 Yes4 No
Block P-VOL Yes2 No1 Yes Yes3 Yes4 No
PSUE Local P-VOL No No1 Yes

Yes3

Yes4 No
Block P-VOL Yes2 No1 Yes Yes3 Yes4 No
SSUS Block S-VOL No No1 No No Yes4 No
SSWS Local S-VOL No No1 Yes No Yes4 No

Note:

  1. Cannot be performed by users. The storage system performs the operation automatically.
  2. If a failure occurs at the primary site, the operation can be performed only when the volume specified as the UR delta resync S-VOL is the UR S-VOL.
  3. The UR S-VOL is also used as the GAD P-VOL only when the UR S-VOL is duplicated using GAD.
  4. Deleting a UR delta resync pair deletes the UR pair.