You should understand the I/O actions on the P-VOL and the S-VOL of a GAD pair.
The following table lists and describes the GAD I/O modes. As shown in the following table, the I/O mode terms displayed by the user interfaces are slightly different.
I/O mode |
Read processing |
Write processing |
||
---|---|---|---|---|
I/O mode |
CCI 1 |
HDvM - SN |
||
Mirror (RL) |
L/M |
Mirror (Read Local) |
Sends data from the storage system that received a read request to the server. |
Writes data to the P-VOL and then the S-VOL. |
Local |
L/L |
Local |
Sends data from the storage system that received a read request to the server. |
Writes data to the volume on the storage system that received a write request. |
Block2 |
B/B |
Block |
Rejected (Replies to illegal requests). |
Rejected (Replies to illegal requests). |
Notes:
|