Select a memory setting pattern

Ops Center Administrator Getting Started Guide

Version
10.8.x
File Size
916 KB
Audience
anonymous
Part Number
MK-99ADM000-13
In an environment where a large number of volumes are attached to servers, an Ops Center Administrator internal service (rainier) can stop working, and the following message is displayed:
Failed to get data from API. Try again.

Why this happens

This sometimes occurs when a large number of volumes are attached to servers. The following table provides estimated configurations for which the symptom might occur.

Average number of servers per volume Number of volumes
1 30,000 or higher
2 12,000 or higher
4 6,000 or higher
8 3,000 or higher
16 1,500 or higher
32 800 or higher
64 400 or higher
128 200 or higher

Select a memory setting pattern

When the above conditions are met, decide on a memory setting pattern (A or B) based on the following table and follow the steps in Changing the memory settings.

Average number of servers per volume Number of volumes Memory settting pattern
1 30,000 or higher A
2 12,000 to 39,999 A
40,000 or higher B
4 6,000 to 19,999 A
20,000 or higher B
8 3,000 to 9,999 A
10,000 or higher B
16 1,500 to 4,999 A
5,000 or higher B
32 800 to 2,399 A
2,400 or higher B
64 400 to 1,199 A
1,200 or higher B
128 200 to 599 A
600 or higher B
Prepare additional usable physical memory based on the memory setting pattern that you selected in the table above:
  • Memory setting pattern A: + 2 GiB
  • Memory setting pattern B: + 6 GiB