You can replace a power supply unit (PSU) as a hot-swappable server component. The server can operate on a single PSU if necessary, making it possible to replace a failed PSU without shutting down the server. If a PSU fails, it should be replaced as quickly as possible, because operating on a single PSU means that there is no redundancy in that area, increasing the risk of an interruption in service to clients.
LED indicators on each PSU indicate the PSU status.
Figure. PSU locations on
NAS Platform Series 4000 rear panel
CAUTION:
You cannot use the power supply from an
HNAS 4060, 4080, and 4100 server in an
HNAS 4040. The
HNAS 4040 server uses the same PSU as the
HNAS 3080 and 3090 servers.
Note: Although the following figure shows the
HNAS 4060, 4080, and 4100 rear panel, the PSU locations are the same on the
HNAS 4040 model.
Item | Description |
---|---|
1 | PSU 1 |
2 | PSU 2 |
Figure. PSU components
Item | Description |
---|---|
1 | PSU fan |
2 | Power plug |
3 | Retaining latch |
4 | Handle |
5 | DC power LED |
6 | Malfunction or failure LED |
7 | AC power LED |