Replace a fan assembly, which is one of the server's hot-swappable components.
- Remove the front bezel. The fan assemblies will then be visible.
-
Identify the fan to be replaced.
Fans are labeled on the chassis, and are numbered 1 and 2, with fan 1 on the left and fan 2 on the right. Refer to the fan status LEDs on front panel of the server (behind the bezel) to see which fan has failed. In the following figure, number 1 indicates the status LED for fan 1 (the left-side fan), and number 2 indicates the status LED for fan 2 (the right-side fan).
Figure. Fan status LEDs
Item Description 1 Fan 1 status LED 2 Fan 2 status LED -
Remove the faulty fan by loosening the thumbscrews (turning them counter-clockwise) until they are loose, then pulling the fan unit straight out of the chassis. (The fan lead connector disengages automatically as you remove the fan assembly.)
Figure. Fan assembly - model 4040
Figure. Fan assembly - models 4060, 4080, and 4100
- Put the new fan assembly into place.
- Gently press the fan assembly back into the chassis. The fan electrical connector will be aligned automatically when the fan is fully inserted into the chassis.
- Secure the fan assembly in position by tightening the thumbscrews (turning them clockwise).
- Replace the front bezel.