The following specifications are for the server. Except for the power and cooling values, these specifications do not reflect differences among models; they are the maximum for all server models. For more detailed specifications of a particular model or configuration, contact your representative.
Physical:
- Weight: 25 kg (55 lb.) with plastic bezel or 26 kg (57 lb.) with metal bezel
- Height: 132 mm. (5 in.)
- Depth (including handles and bezel): 725 mm. (28.6 in.)
- Width: 440 mm. (17.3 in.)
- Rack space required: 3U (5.25 in.)
Note: A rack unit, or U, is a unit of measure that is used to describe the height of equipment intended to be mounted in a rack. One rack unit is equivalent to 1.75 inches or 44.45 millimeters.
Power and cooling:
Note: The power supplies and cooling fans noted in the following table are hot-swappable.
Item | Model 4040 | Models 4060, 4080, and 4100 |
---|---|---|
Power supplies | 2 | 2 |
Cooling fans | 2 | 2 |
Current drawn: |
110 VAC: 2.6A to 3.1A 208 VAC: 1.3A to 1.7A 230 VAC: 1.2A to 1.5A |
110 VAC: 2.9A to 3.5A 208 VAC: 1.5A to 1.9A 230 VAC: 1.4A to 1.7A |
Power supply rating | 450W | 550W |
Average thermal (BTU per hour) | 853 | 938 |
Max thermal (BTU per hour) | 1057 | 1194 |
Max power usage | 310W | 350W |
Other thermal:
- Temperature range (operational): 10° to 35° C (50° to 95° F)
- Maximum rate of temperature change per hour (operational) 10° C (18° F)
- Temperature range (storage): -10° to 45° C (14° to 113° F)
- Maximum rate of temperature change per hour (storage) 15° C (27° F)
- Temperature range (transit): -20° to 60° C (-4° to 140° F)
- Maximum rate of temperature change per hour (transit) 20° C (36° F)
Airflow:
Fan speed | Single fan in free air | Single fan at 33% perforation | Two fans at 33% perforation | |||
---|---|---|---|---|---|---|
m^3/min | CFM | m^3/min | m^3/min | CFM | ||
@ 100% | 7.40 | 261.22 | 2.96 | 5.92 | 208.98 | Not used |
@ 2/3 | 4.93 | 174.15 | 1.97 | 3.95 | 139.32 | Fan failure or over temperature |
@1/3 | 2.47 | 87.07 | 0.99 | 1.97 | 69.66 | Normal operation |
Figure. Airflow performance curves
Item | Description |
---|---|
1 | Performance curves, pulse width modulation (PWM) = 100% |
2 | Static pressure (Pa) |
3 | Airflow (m3/minute) |
Humidity:
- Operational: 20-80%
- Storage: 10-90%
- Transit: 5-95%
Noise: A-weighted Sound Power Level, Lwa (db re 1pW):
- Typical: 71
- Max: 81
Shock and vibration:
- Optional random vibration: 10 to 350 Hz @ 0.18 Grms
- Non-operational sinusoidal vibration: 60 to 350 Hz: @ 1g
- Non-operational shock: 3g 11ms, half sine
Packaged transport specification:
- Drops from 356mm and 508mm as per ASTM D5276
- Vibration at up to 0.53 Grms as per ASTM D4728
Altitude:
- Maximum of 2000 meters