Server specifications

NAS Platform and Unified Storage Series 4000 Hardware Reference

Version
14.8.x
Audience
anonymous
Part Number
MK-92HNAS030-28

The following specifications are for the server. Except for the power and cooling values, these specifications do not reflect differences among models; they are the maximum for all server models. For more detailed specifications of a particular model or configuration, contact your representative.

Physical:
  • Weight: 25 kg (55 lb.) with plastic bezel or 26 kg (57 lb.) with metal bezel
  • Height: 132 mm. (5 in.)
  • Depth (including handles and bezel): 725 mm. (28.6 in.)
  • Width: 440 mm. (17.3 in.)
  • Rack space required: 3U (5.25 in.)
    Note: A rack unit, or U, is a unit of measure that is used to describe the height of equipment intended to be mounted in a rack. One rack unit is equivalent to 1.75 inches or 44.45 millimeters.
Power and cooling:
Note: The power supplies and cooling fans noted in the following table are hot-swappable.
Item Model 4040 Models 4060, 4080, and 4100
Power supplies 2 2
Cooling fans 2 2
Current drawn:

110 VAC: 2.6A to 3.1A

208 VAC: 1.3A to 1.7A

230 VAC: 1.2A to 1.5A

110 VAC: 2.9A to 3.5A

208 VAC: 1.5A to 1.9A

230 VAC: 1.4A to 1.7A

Power supply rating 450W 550W
Average thermal (BTU per hour) 853 938
Max thermal (BTU per hour) 1057 1194
Max power usage 310W 350W
Other thermal:
  • Temperature range (operational): 10° to 35° C (50° to 95° F)
  • Maximum rate of temperature change per hour (operational) 10° C (18° F)
  • Temperature range (storage): -10° to 45° C (14° to 113° F)
  • Maximum rate of temperature change per hour (storage) 15° C (27° F)
  • Temperature range (transit): -20° to 60° C (-4° to 140° F)
  • Maximum rate of temperature change per hour (transit) 20° C (36° F)
Airflow:
Fan speed Single fan in free air Single fan at 33% perforation Two fans at 33% perforation
m^3/min CFM m^3/min m^3/min CFM
@ 100% 7.40 261.22 2.96 5.92 208.98 Not used
@ 2/3 4.93 174.15 1.97 3.95 139.32 Fan failure or over temperature
@1/3 2.47 87.07 0.99 1.97 69.66 Normal operation
Figure. Airflow performance curves

Item Description
1 Performance curves, pulse width modulation (PWM) = 100%
2 Static pressure (Pa)
3 Airflow (m3/minute)
Humidity:
  • Operational: 20-80%
  • Storage: 10-90%
  • Transit: 5-95%
Noise: A-weighted Sound Power Level, Lwa (db re 1pW):
  • Typical: 71
  • Max: 81
Shock and vibration:
  • Optional random vibration: 10 to 350 Hz @ 0.18 Grms
  • Non-operational sinusoidal vibration: 60 to 350 Hz: @ 1g
  • Non-operational shock: 3g 11ms, half sine
Packaged transport specification:
  • Drops from 356mm and 508mm as per ASTM D5276
  • Vibration at up to 0.53 Grms as per ASTM D4728
Altitude:
  • Maximum of 2000 meters