Hardware sizing based on system scale

Ops Center Quick Start Guide

Version
11.0.x
Audience
anonymous
Part Number
MK-99OPS006-07
ft:lastEdition
2026-03-16

The following table contains guidelines for determining the size of your environment based on the number of monitoring targets. Based on the sizing and scalability guidelines, you can identify the hardware requirements and scale your environment to meet workload demands.

Monitoring storage systems only

System scale Maximum number of resources
Storage
Volume* Storage Volume Pair
Small scale 5,000 3 300
Medium scale 20,000 19 600
Large scale 50,000 30 1,200
* Total number of volumes for all storage systems.

Note:

To manage a system larger than that described in "Large scale", please contact us separately.

The system scale requirements for just monitoring storage systems are the same for all Ops Center products. For details, see the Hitachi Ops Center System Requirements.

Monitoring hypervisors and switches

System scale

Maximum number of resources
Hypervisor FC Switch
ESX VM Switch Total Port count
Level 1

8

120

8

384

Level 2

25

375

25

1,200

Level 3

50

3,000

40

1,920

The memory and disk space requirements vary depending on the managed resources. For example:
  • a large number of volumes require a sizable database.
  • if you decrease the interval at which you obtain performance information, the volumes occupy more disk space in the database.

Monitoring storage systems by using RAID Agent (Windows)

System scale

Maximum number of resources
Storage
Storage Volume

Small scale

1

5,000

Medium scale

5

35,000

Large scale

10

70,000

Larger scale 40 200,000

Use this table to perform hardware sizing based on the scale of the system to be monitored by using RAID Agent (Windows).

When using the Analyzer Adapter

System scale

Maximum number of resources
Storage
Storage Volume

Extra Small scale

2

1,000

Small scale

5

5,000

Medium scale

10

10,000

Large scale 30 50,000