You can define custom thresholds for
Analyzer detail view dashboard resource indicators from the Manage menu. The thresholds that you set in this window appear in the Indicator Thresholds menu of the Add Indicator window.
Dynamic thresholds
Dynamic thresholds are supported for certain devices. You can add the threshold on the storage port throughput based on the speed of the switch port that the storage port is connected to.
Analyzer detail view currently supports the dynamic thresholds for the following probes, resource types, and metrics.
| Probe |
Resource type |
Metric |
| Hitachi Enterprise Storage |
RAID Port |
Transfer Rate |
| EMC VMAX |
VMAX Port |
MBps Ops |
-
In the application bar, click
the Manage menu.
-
In the
Administration section, click the
Manage Thresholds link.
The
Manage Thresholds window opens.
-
In the
Manage Thresholds window, supply the following information:
- Select Probe Select the probe from the list.
- Select Resource Type Select the resource from the list.
- Select Metric Select the metrics for the selected probe and resource type.
- Add Indicator Thresholds Click
Add Thresholds and type the label for the
threshold, and then set the warning and critical thresholds as follows:
- Type the threshold name and set the threshold value.
- Configure Advanced options to set threshold direction
(Forward or Reverse):
- For Forward Threshold, the critical threshold should be greater
than warning threshold. In this case, the threshold is
violated when the metric value exceeds the defined
threshold. By default, the threshold direction is
Forward.
- For Reverse Threshold, the warning threshold should be greater than
critical threshold. In this case, the threshold is
violated when the metric value is less than the defined
threshold. Reverse direction thresholds are useful when
evaluating metrics like Read Hit for VMAX Volume or
Cache Usage. If the Read Hit rate falls below the
threshold, the cache is underutilized and performance
suffers.
For devices that support dynamic thresholds, the following additional options are displayed:
- Specify Dynamic Threshold Value Select to specify a dynamic threshold value.
- Select Resource Path Select the appropriate switch port path.
- Select Attribute Select the attribute and provide the Warning and Critical threshold values (percentage).
-
Click