Example 1: changing the threshold of the HDD
09xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,SVP,uid=user-name,,
[Information],ORM Value,Alter,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Type=7days
+{Read Err.(Unrecovered),Read Err.(Recovered), Seek Err.(Recovered),
Seek Err.(Unrecovered),Not Ready, Other Errors}={15,1.00e-008,100,10,10,10}
++PDEV=[HDD000-01,HDD000-02],Num. of PDEVs=2
Example 2: changing the threshold of the SSD when drive type is SLxxx-MxxxSS/SNxxx-RxxxNC/SPxxx-YxxxNC
09xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,SVP,uid=user-name,,[Information],ORM Value,Alter,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Type=Total
+{Total Defect Count,Used Endurance Indicator}={160000,(99,90)}
++PDEV=[HDD000-03],Num. of PDEVs=1
Example 3: changing the threshold of the SSD when drive type is other than the ones in Example 2
09xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,SVP,uid=user-name,,[Information],ORM Value,Alter,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Type=Total
+{Total Defect Count}={15}
++PDEV=[HDD000-01,HDD000-02],Num. of PDEVs=2
Example 4: changing the threshold of the FMD when drive type is NFHxx-Pxxxxx
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,,
[Information],ORMValue,Alter,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Type=Today
+{Total Defect Count,Reboot Error,DMA Error,Memory Error, Uncorrected Error,Used Endurance
Indicator,Battery Error, FMD Battery Life Indicator}={0,2,10,500,512,(0,0),1,0}
++PDEV=[HDD000-03],Num. of PDEVs=1
Example 5: changing the threshold of the FMD when drive type is NFHxx-Qxxxxx
09xx,YYYY/MM/DD,HH:MM:SS.xxx, 00:00,SVP,uid=user-name,,[Information],ORM Value,Alter,Normal end,
from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx
+Type=Today
+{Total Defect Count,Reboot Error,DMA Error,Memory Error, Uncorrected Error,Used Endurance
Indicator,Capacitor Error}= {0,2,10,500,512,(0,0),1}
++PDEV=[HDD000-03],Num. of PDEVs=1
Example 6: Error Reset
09xx,YYYY/MM/DD,HH:MM:SS.xxx,00:00,SVP,uid=user-name,,[Information],ORM Value,Error Reset,Normal end, from=xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx:xxxx,,Seq.=xxxxxxxxxx +PDEV=HDD000-01
Basic Information
|
Parameter |
Description |
|---|---|
|
Alter |
Change the threshold of ORM (Online Read Margin) |
|
Error Reset |
Indicates Error Reset |
Detailed Information
|
Item |
Description |
|---|---|
|
Type |
The period of time to acquire the result of threshold diagnosis using the read diagnosis function Today: Current day only, 7days: 7 days, Total: Every operating days |
|
Read Err. (Unrecovered) |
The threshold of the Read Error (Unrecovered) |
|
Read Err. (Recovered) |
The threshold of the Read Error (Recovered) |
|
Seek Err. (Recovered) |
The threshold of the Seek Error (Recovered) |
|
Seek Err. (Unrecovered) |
The threshold of the Seek Error (Unrecovered) |
|
Not Ready |
The threshold of the Not Ready status. |
|
Other Errors |
The threshold of Other Errors. |
|
Total Defect Count |
The threshold of the Total Defect Count |
|
Used Endurance Indicator |
The threshold of the Used Endurance Indicator |
|
Reboot Error |
The threshold of the Reboot Error |
|
DMA Error |
The threshold of the DMA Error |
|
Memory Error |
The threshold of the Memory Error |
|
Uncorrected Error |
The threshold of the Uncorrected Error |
|
Battery Error |
The threshold of the Battery Error |
|
FMD Battery Life Indicator |
The threshold of the FMD Battery Life Indicator |
|
Capacitor Error |
The threshold of the Capacitor Error |
|
PDEV |
The mounting location of the PDEV (physical device) that is the target of Alter or error reset |
|
Num. of PDEVs |
The number of PDEVs (physical devices) |