Troubleshooting firmware upgrade issues with the DS120 G2 and DS220 G2 servers

Unified Compute Platform (UCP) Advisor Administration Guide

Version
4.6.x
Audience
anonymous
Part Number
MK-92UCP119-15
ft:lastEdition
2024-09-24
Use the following guidelines and suggested steps to resolve firmware upgrade issues with the following servers:
  • DS120 G2/DS220 G2
Condition:
The upgraded BMC firmware does not validate.
What it Means:
The dual image is not configured properly on the BMC.
Corrective Action:
Perform the following steps to verify that the dual image is configured properly on the BMC.
  1. In a web browser, log on to the BMC.
  2. Browse to Maintenance > Dual Image Configuration.
  3. Select the Most recently updated firmware option.
    Dual image configuration

  4. Save the configuration.
  5. Retry the upgrade operation.