Use the following guidelines and suggested steps to resolve firmware upgrade issues on the HA800 G2/G3 series server models that occur due to server configuration.
- Condition 1:
- Unable to upgrade the server firmware due to the following error:
Unable to upgrade the firmware on server <server IP address> because of Error response from the upgrade server <workFlowId: 109>. Check configurations.
- What it Means:
- The iLO must be reset.
- Corrective Action:
- Reset the iLO, and then re-run the firmware upgrade operation on the target server:
- Using SSH, log on to the iLO of the target server.
- Navigate to the /map1 directory, and then run the following command:
reset
- Wait 10 minutes.
- On the UCP Advisor page, click the Refresh icon.
- Re-run the Upgrade Firmware operation.
- Condition 2:
- Unable to access the ESXi server even though the UCP AdvisorTasks tab displays a successful upgrade message.
- What it Means:
- The firmware upgrade was unsuccessful.
- Corrective Action:
- Using SSH, log on to the server's iLO.
- Click the Power button and then select Cold Boot.
- Wait for the server to power on.
- Log on to the vCenter and verify that the ESXi host for the specific server is in the Connected state.
- Re-run the Upgrade Firmware operation for the specific server.