You can edit the BMC settings for SNMPv3 on individual servers. You can also disable SNMPv3 per local user for all selected servers.
- Browse to the UCP system where you want to edit the SNMPv3 settings for a server, and then click Compute.
- Select the server, and then click the Edit BMC Settings icon.
- From the Select BMC setting to change list, select SNMPv3 settings.The Selected Server table lists the current SNMPv3 settings for the server.Note: Disable SNMPv3 is not available for HA810/HA820 G2 and HA805/ HA810/HA815/HA820/HA825/HA840 G3 server models.
- Edit the SNMPv3 settings, as needed, or you can click Disable SNMPv3 to disable SNMPv3 per user on the selected servers.
- Username
- The SNMPv3 username.
- Access Level
- The level of access for the SNMPv3 user: Read/Write, Read Only.Note: Access Level is not available for HA810/ HA820 G2 and HA805/ HA810/HA815/HA820/HA825/HA840 G3 server models, but these server models have Auth Passphrase and PrivacyPassPhrase.
- Auth Protocol
- The SNMPv3 authentication protocol: SHA, MD5, SHA256, SHA384, and SHA512.Note:
- HA810/ HA820 G2 and HA805/ HA810/HA815/HA820/HA825/HA840 G3 server models have only SHA and MD5.
- DS120 G2 and DS220 G2 servers support only SHA256, SHA384, and SHA512 authentication protocols.
- Privacy Protocol
- The SNMPv3 privacy protocol: AES, DES.
- Click Submit.