Discovering I/O cards on HA800 G2 and G3 series servers

Unified Compute Platform (UCP) Advisor Administration Guide

Version
4.5.x
Audience
anonymous
Part Number
MK-92UCP119-13
ft:lastEdition
2024-03-11

The I/O cards are automatically discovered when you onboard the HA810/HA820 G2 and HA805/ HA810/HA815/HA820/HA825 G3 servers to a UCP system; however, you can also manually discover new I/O cards.

Note:
  • I/O card discovery is not supported on HA840 G3 server model.
  • I/O card discovery is also supported on bare metal servers.
  • Upload the firmware bundle. See Uploading firmware.
  • Verify that the servers have been onboarded with either the BMC details, or with both the BMC and ESXi details.
  • Verify that BMC port 443 on the servers is open and accessible to the Master Node and Worker Node VMs.
  1. Browse to the UCP system where you want to discover the I/O cards, and then click Compute.
  2. Select one or more HA810 /HA820 G2 or HA805/ HA810/HA815/HA820/HA825 G3 servers, and then click the Discover I/O cards icon.
  3. Select the discovery method: Parallel or Sequential. The default selection is Parallel.
  4. Enter Submit, and then click Submit.

    The I/O card discovery process on HA810/HA820 G2 and HA805/ HA810/HA815/HA820/HA825 G3 servers is non-disruptive; the servers are not powered-off and not placed in Maintenance mode. You can monitor the status of the discovery process from the Tasks console.

    Note:
    • When I/O card discovery is sequentially initiated for multiple servers, some I/O card discovery tasks for a subsequent server may start before the task for the previous server has completed.
    • The I/O card discovery for HA810/HA820 G2 and HA805/ HA810/HA815/HA820/HA825 G3 servers does not populate the following fields: “TYPE”, “VENDOR”, “ESXI”, and “Upgrade Available”.
All the discovered I/O cards are displayed on the I/O Cards tab for each server, respectively.