Compute inventory

Unified Compute Platform (UCP) Advisor Administration Guide

Version
4.5.x
Audience
anonymous
Part Number
MK-92UCP119-13
ft:lastEdition
2024-03-11

The compute inventory view displays general information and management operations for the compute nodes in the UCP system inventory.

To view the compute inventory, browse to the UCP system where you want to view the inventory, and then select Compute.
  • Click the List or Tile icons to change the inventory view.

Image of Compute summary tile view


Image of Compute summary list view

In Tile view, the following general information for each compute node is displayed:
Model
The model name of the compute device.
Serial
The serial number of the compute device.
BIOS
The version of the BIOS installed on the compute device.
Firmware
The firmware installed on the compute device.
BMC Address
The BMC IP address or host name for the compute device.
BMC MAC
The BMC MAC address for the compute device.
Host Address
The IP address or host name for the host.
CPLD Version
The CPLD version for the compute device.
Label
The label for the compute device.
Note: After onboarding devices using an onboarding worksheet with predefined server labels, in Tile view on the Compute inventory page, the tile header now displays the server serial number instead of the server label.
Node Type
The type of compute device: Compute or Management.
In List view, the following additional general information for each compute node is displayed:
Host OS
The operating system installed on the host.
BIOS/BMC/CPLD Firmware
The BIOS, BMC, and CPLD firmware versions installed on the compute device.
Server Tags
The tags assigned to the compute device.
Status
The onboard status of the compute device.
Power Status
The power status of the server.

Click any compute device tile to display summary and component information through various tabs. For example, the summary tab displays the current state and location of the compute device, the version numbers of its software components, the state of its hardware components, and any related alerts. The component tabs display information about the compute hardware, such as location, model name and manufacturer, operation parameters, and status. You can also view vSAN datastore information and event logs associated with the compute device.

The additional management actions enable you to refresh the compute device information, set boot options, power-off/power-on servers, reset the power, reset the BMC, edit the BMC password, replace a server, upgrade firmware, and launch a remote console to perform other administrative tasks.


Image displaying the Summary tab that lists compute node summary information

The following summary and component information for each compute node is displayed:
BIOS Version
The BIOS version installed on the compute device.
BMC Address
The Baseboard Management Controller (BMC) IP address or host name for the compute device.
BMC Firmware Version
The BMC firmware version installed on the compute device.
BMC MAC Address
The BMC MAC address for the compute device.
Chipset
The chipset used by the compute device.
Note: The chipset is displayed as N/A for the DS120/DS220 G2 and HA800 G2/G3 series server models as it is not supported.
Cluster
The cluster to which the compute ESXi host is assigned.
CPLD Version
The version of the Complex Programmable Logic Device (CPLD) firmware installed on the compute device.
Note: This information is not displayed for HA800 G2/G3 series server models as it is not supported.
Datacenter
The datacenter where the compute ESXi host resides.
DCPMM
The status of the data-centric persistent memory module (DPMM): Present, N/A.
Note: This information is listed as Present if it is installed on the server or N/A if it is not available on the server. This information is listed only for DS120/ DS220, DS120/DS220 G2, DS225, and DS240 server models.
Fan Status
The current status of the fan: Normal, Standby, Busy, Disabled, N/A, Unknown, Absent, Degraded, Exceeds Threshold, Critical, Fault.
Hard Disk Status
The current status of the hard disk used: Normal, Standby, Busy, Disabled, N/A, Unknown, Absent, Degraded, Exceeds Threshold, Critical, Fault.
Host Address
The IP address or host name for the host.
Host Name
The name of the host operating system. It will only display for hosts that are OS-provisioned by UCP Advisor.
Host OS
The operating system of the compute ESXi host hypervisor.
Model
The model name of the compute device.
NIC MAC Address
The Media Access Controller (MAC) address for the Network Interface Controller (NIC).
Number of CPUs
The number of CPUs used by the compute device.
Number of GPUs
The number of graphical processing units (GPUs) used by the compute device.
Note:
  • The latest version of the NVIDIA driver is required to obtain GPU memory information.
  • This information is listed only for DS120/ DS220, DS120/DS220 G2, DS220, and DS240 server models.
Onboard Status
The current onboard status of a compute node: Maintenance, Onboarded, Not Onboarded, Locked, Updated, Unrecognized Device, Unreachable, Normal, ERROR, Onboarding.
Remote Syslog Server
The IP address of the vRealize Log Insight instance that you have attached to the UCP system.
Serial
The serial number of the compute device.
Tags
Optional labels you can assign to compute nodes to simplify list filtering.
Temperature Status
The current status of the temperature: Normal, Standby, Busy, Disabled, N/A, Unknown, Absent, Degraded, Exceeds Threshold, Critical, Fault.
Total Memory
The total physical memory available to the compute device.
vCenter
The vCenter server to which the compute host is assigned.
Voltage Status
The current status of the voltage: Normal, Standby, Busy, Disabled, N/A, Unknown, Absent, Degraded, Exceeds Threshold, Critical, Fault.
Note: This information is not displayed for HA800 G2/G3 series server models.
WWN
The unique World Wide Name (WWN) identifier of the compute node.

From the various tabs, you can access the following component information:

  • BMC: this view shows the AD settings, NTP settings, SNMP, and SNMPv3 settings.
    Note:
    • Edit SNMP settings is not applicable on DS120/DS220 G2 and HA805/HA810/HA815/HA820/HA825 G3 server models.
    • Edit NTP settings is not supported on HA810/ HA820 G2 and HA805/HA810/HA815/HA820/HA825 G3 server models.

    Image displaying the BMC screen that lists AD Settings, NTP Settings, SNMP, and SNMPv3 Settings

  • BIOS: this view shows the existing boot settings and CPU settings in the Summary tab, as well as an Apply BIOS Settings button where you can update the existing boot settings and CPU settings, and BIOS templates in the BIOS Template tab, as well as Create BIOS Template, Edit BIOS Template, Clone BIOS Template, and Delete BIOS Template options.
    Image displaying BIOS settings such as boot settings and CPU settings


    Image displaying BIOS templates in BIOS Template tab

  • CPU
    Image displaying the CPU screen that lists compute node CPU information

  • GPU
    Note: The NVIDIA GPU VIB (vSphere Installation Bundle) must be installed and configured on the ESXi host to display the GPU memory information.

    Image displaying the GPU screen that lists compute node GPU information

  • FRU
    Note: The Date of Manufacture is not displayed for the DS120/ DS220, DS120/DS220 G2, DS220, and DS240 server models.

    Image displaying the FRU screen that lists compute node FRU information

  • Fan
    Image displaying the Fan screen that lists compute node fan information

  • Temperature
    Image displaying the Temperature screen that lists compute node temperature information

  • Voltage
    Image displaying the Voltage screen that lists compute node voltage information

    Note: This feature is not supported on the following compute nodes: HA810/HA820 G2, HA805/HA810/HA815/HA820/HA825 G3.
  • Memory
    Image displaying the Memory screen that lists compute node memory information.

  • I/O Cards
    • Note:

      The I/O cards on HA810/HA820 G2 and HA805/HA810/HA815/HA820/HA825 G3 server models are automatically discovered when you onboard the servers.


    Image displaying the I/O Cards screen

  • Local Drives: this view shows system drives and RAID drives.
    Note:

    Drives connected to SAS Controller (SAS Drives) or NVMe drives are not supported.

    This feature is partially supported on HA810 G2 and HA820 G2 - the view only shows RAID drives and not system drives for these servers.

    For a visual reference of the physical location of the drive slot numbers per server model, see Local drive slot numbering.


    Image displaying the Local Drives screen that lists compute node local drive information

  • vSAN Datastores: this view shows Host Config, Datastore, Physical Storage Devices, and Other Storage Devices.
    Note: The vSAN Datastores information is populated only when the vSAN configuration is enabled on a compute server that is onboarded with ESXi details. The vCenter must be attached to the UCP system to populate the vSAN Datastores information.

    Image displaying the VSAN Datastores screen that lists compute node VSAN datastore information

  • Events
    Image displaying the Events screen that lists compute node event information