The following table is used to calculate the amount of data of the output SMF records.
| Record (subtype) |
Size per record (in bytes) |
Number of records per interval |
|---|---|---|
| LDEV (subtype 2) |
header-length + (number-of-collection-target-LDEVs-in-the-CU LDEV-section-length) |
Number of collection target CUs |
| MPU (subtype 3) |
header-length + MPU-section-length + (number-of-CLPRs |
Number of collection target MPUs |
| PGRP (subtype 4) |
header-length + (number-of-parity-groups-in-the-storage-system PGRP-section-length) |
Number of collection target storage systems |
| PORT (subtype 5) |
header-length + (number-of-ports-in-the-storage-system PORT-section-length) |
Number of collection target storage systems |
| MPRANK20 (subtype 6) |
header-length + (number-of-MPs-in-the-storage-system MPRANK20-section-length) |
Number of collection target storage systems |
- Note:
- header-length = standard-header-length + self-defining-section-length + product-section-length
Add the calculated sizes to the output sizes of other programs to determine the sizes of the SMF dataset, SMF log stream, and SMF buffer.