List of examples of changing the metric collection environment and the required operations

Mainframe Analytics Recorder User Guide

Version
10.1.x
Audience
anonymous
Part Number
MK-92HC226-08
ft:lastEdition
2026-01-30
The following table lists examples of changing the metric collection environment and the required operations.
Table. List of examples of changing the metric collection environment and the required operations

Examples of changes

Whether operation is required

Scan

Change of metric collection parameters

Execution of REFRESH

Adding a storage system to the collection targets

Required

(Scan the storage systems to be added.)

Required

Required

Adding volumes not in the disk configuration definition file to the collection targets

Required

(Scan the volumes to be added.)

Required if the LDEVFILT parameter is specified.

Changing the collection scope within volumes in the disk configuration definition file

Not required

Required

Adding a volume added to an SMS storage group to the collection targets

Required

(Scan the SMS storage group again.)

Not required

Excluding from the collection target volumes that were deleted from an SMS storage group

Required

(Delete the disk configuration definition file, and then scan the storage system again.)

Not required

Excluding volumes that were deleted from the system from the collection targets

Required

(Delete the disk configuration definition file, and then change the range of scanning, and scan the storage system again.)

Not required

Adding I/O destination devices

Required

(Scan the volumes to be added.)

Required

Changing the interval and metrics

Not required

Required

Tip: When you change metric collection parameters, execute the DISPLAY command to check the parameter file name (member name) of the running metric collection program.
F RS1,D,PARM
Tip: When you want to change the member names of metric collection parameters, specify member names by using the MEMBER parameter of the REFRESH command.
F RS1,RE,M=P150325